CLINICAL TRIAL / NCT06029660
AAA-SHAPE Pivotal Trial: Abdominal Aortic Aneurysm Sac Healing and Prevention of Expansion
- Interventional
- Active
- NCT06029660
Contact Information
AAA-SHAPE Pivotal Trial: Abdominal Aortic Aneurysm Sac Healing and Prevention of Expansion
To determine the safety and effectiveness of IMPEDE-FX RapidFill to increase the percentage of subjects with shrinkage of the abdominal aortic aneurysm sac when used as an adjunct to on-label endovascular aneurysm repair (EVAR) stent graft treatment in trial subjects considered candidates for elective EVAR.
Gender
All
Age Group
18 Years and up
Accepting Healthy Volunteers
No
Inclusion Criteria:
1. ≥18 years of age
2. A candidate for elective EVAR of an infrarenal fusiform aortic aneurysm ≥5.5 cm in
diameter in men and ≥5.0 cm in women;
3. Thrombus burden (percentage of the AAA sac occupied by thrombus) <50%, based on
pre-procedure CTA
4. Maximum Lumen diameter within the AAA sac of ≥40mm.
5. The predicted minimum number of IMPEDE-FX RapidFill Implants for the subject is
≤200.
Exclusion Criteria:
General
1. An inability to provide informed consent.
2. Enrolled in another clinical study that could interfere with the outcomes being
studied in this trial.
3. Unable or unwilling to comply with study follow-up requirements.
4. Prisoner or member of other vulnerable population
Anatomical
1. Concomitant iliac artery ectasia or aneurysm
2. Vascular disease and/or anatomy that preclude the safe access and positioning of a
catheter to deliver the investigational product into the AAA sac.
3. Ruptured, leaking, inflammatory or mycotic (infected) aneurysm.
4. Connective tissue disorder (e.g., Marfan's syndrome)
5. Aneurysmal disease of the descending thoracic aorta
6. Excessive calcification at the aortic bifurcation to common/internal iliac
bifurcation, that might lead to access difficulties
EVAR/Procedural
1. Use of aortic stent grafts other than the Gore Excluder AAA Endoprosthesis, Gore
Excluder Conformable AAA Endoprosthesis, Cook Zenith Flex AAA Endovascular Graft,
Medtronic Endurant II and Endurant IIs Stent Graft, or the Terumo TREO Stent Graft
to treat the AAA
2. Use of an aortic stent graft other than those specified1 for a particular site
3. Planned use of the chosen stent graft outside its instructions for use (IFU)
4. Use of fenestrated stent grafts or chimney techniques
5. Use of the Heli-FX EndoAnchor system
6. Use of embolic devices other than the investigational product to embolize the AAA
sac
7. Use of embolic products to prophylactically or concomitantly embolize the inferior
mesenteric artery, lumbar arteries, renal accessory arteries, or internal iliac
arteries
8. Inability to land the distal-most portion of the EVAR stent graft limbs, including
extensions, above the internal iliac arteries
Medical History/Conditions
1. Coagulopathy or uncontrolled bleeding disorder
2. Serum creatinine level >2.5 mg/dL
3. Cerebrovascular accident within 3 months prior to the procedure
4. Myocardial infarction and/or major heart surgery within 3 months prior to the
procedure
5. Atrial fibrillation that is not well rate controlled
6. Life expectancy of <2 years post-procedure
7. Known hypersensitivity or contraindication to platinum, iridium, or polyurethane.
8. Have active infection at the time of the index procedure documented by pain, fever,
drainage, positive culture, or leukocytosis (WBC >11,000/mm3)
9. A condition that inhibits radiographic visualization during the implantation
procedure
10. History of allergy to contrast medium that cannot be managed medically, or subject
is unable to have a CT with contrast for any reason.
11. Uncontrolled co-morbid medical condition, including mental health issues, that would
adversely affect participation in the trial
12. Pregnant or lactating female: for females of child-bearing potential, based on a
positive pregnancy test within 7 days prior to the procedure or refusal to use a
medically accepted method of birth control for the duration of the trial